Secure openings in ranked wall surfaces, floorings, and ceilings against the spread of fire and also smoke utilizing the latest demands in NFPA 80, Requirement for Fire Doors and also Various Other Opening Protectives.


In a fire occasion, NFPA 80 compliance can make all the distinction in owner life security and also building security. That's why NFPA 80 is referenced by NFPA 101 ®, Life Safety And Security Code ®, version building ordinance, as well as fire codes across the country and also around the world. Correct installment of openings in fire rated assemblies is important-- and also fire doors as well as fire home windows are needed to be evaluated as well as checked yearly to ensure they remain in proper functioning condition and also can assist confine a fire ought to one take place.


If you're responsible for building fire safety, there's no replacement for the current version of the requirement.


NFPA 80's stipulations help you ensure appropriate setup, examination, testing, and also maintenance of fire door settings up, fire home window assemblies, fire dampers, textile fire safety curtains, and fire protective drape settings up. When adjustments take place, every person needs to understand-- from producers to developers, designers, service providers, AHJs, fire door assessors, as well as structure owners. In the 2019 version:


· New interpretations for assessment mark and also field tag assistance customers apply upkeep, screening, as well as evaluation arrangements.
Updated arrangements in Chapter 4 identify task site preparation of fire doors for fire pins.
·Brand-new arrangements in Phase 4 cover gauging clearance under the bottom of fire doors, as well as a brand-new demand addresses bottom clearance with the visibility of latching equipment tools.
·The extent of Phase 5 is expanded to deal with fire safety drape assemblies, and a new section in Phase 5 addresses inspection marks.
·While the requirement currently calls for damper makers' installation and also upkeep guidelines be maintained on site for brand-new damper setups, updated Chapter 19 additionally has the current needs for the evaluation, testing, and maintenance of fire as well as combination fire/smoke dampers and adds a remote evaluation method.
·New language clarifies application of inspection demands for solitary inaccessible dampers.
·Annex An includes modified and also new figures for normal steel door framework installations.
·All referenced publications as well as drawn out sections are current.

From fire doors as well as fire home windows to material fire safety curtains and also fire dampers, NFPA 80 covers it all.


Doors and also other fire-rated opening protectives that are not installed and also kept according to NFPA 80 are at risk for jeopardizing the fire obstacle. Protect structures as well as passengers by staying up-to-code. (Softbound, 102 pp., 2019)

Fascinated in various other versions of NFPA 80? Make use of the fall menu over to select the version year you require.

Table of Contents (2019 Current Version)

· NFPA ® 80 Requirement for Fire Doors and also Other Opening Protectives, 2019 Version


Chapter 1 Administration


1.1 Scope.
1.2 Purpose.
1.3 Retroactivity.
1.4 Similarity.


Chapter 2 Referenced Publications


2.1 General.
2.2 NFPA Publications.
2.3 Other Publications.
2.4 References for Extracts in Required Sections.


Phase 3 Interpretations.


3.1 General.
3.2 NFPA Authorities Definitions.
3.3 General Definitions.


Phase 4 General Needs.


4.1 General Limitations.
4.2 Detailed as well as Classified Products.
4.3 Classifications and also Kinds Of Doors.
4.4 Polishing Material in Fire Doors.
4.5 Fire Resistance-- Ranked Polishing in Doors and also Windows.
4.6 Classification of Equipment for Fire Doors.
4.7 Actuation Gadgets for Fire Doors, Fire Shutters, as well as Fire Windows.
4.8 Sustaining Building.


Chapter 5 Assessment, Screening, and Upkeep.


5.1 General.
5.2 Assessment and Screening.
5.3 Retrofit Operators.
5.4 Performance-Based Choice.
5.5 Upkeep.


Phase 6 Moving Doors with Builders Hardware.


6.1 Doors.
6.2 Sustaining Building and construction.
6.3 Openings.
6.4 Assembly Parts.
6.5 Application, Installment, and also Modification.


Chapter 7 Moving Doors with Fire Door Hardware.


7.1 Doors.
7.2 Sustaining Building and construction.
7.3 Openings.
7.4 Setting up Parts.


Phase 8 Horizontally Gliding Doors.


8.1 Doors.
8.2 Sustaining Building and construction.
8.3 Openings. (Reserved).
8.4 Setting up Elements.


Chapter 9 Special-Purpose Horizontally Moving Accordion or Foldable Doors.


9.1 Doors.
9.2 Sustaining Building and construction.
9.3 Clearances Around Openings.
9.4 Assembly Parts.


Chapter 10 Vertically Sliding Fire Doors.


10.1 Doors.
10.2 Sustaining Construction.
10.3 Clearances.
10.4 Assembly Elements.


Chapter 11 Rolling Steel Doors.


11.1 Doors.
11.2 Supporting Building and construction.
11.3 Openings.
11.4 Assembly Elements.
11.5 Climate Security.


Phase 12 Fire Shutters.


12.1 Types.
12.2 Needs.
12.3 Climate Protection.


Chapter 13 Solution Counter Fire Doors.


13.1 Doors.
13.2 Sustaining Building and construction.
13.3 Counters.
13.4 Automatic Closing.


Chapter 14 Hoistway Doors for Elevators and also Dumbwaiters.


14.1 Doors.
14.2 Kinds of Doors.
14.3 Hoistway Door Vision Panels.
14.4 Door Procedure.


Phase 15 Chute Doors.


15.1 Chute Discharge Doors.
15.2 Chute Intake Doors.
15.3 Limited-Access Gravity Chutes.
15.4 Pneumatically-driven Chute Intake Doors.


Chapter 16 Accessibility Doors.


16.1 Doors.
16.2 Types of Doors.


Phase 17 Fire Windows.


17.1 Windows.
17.2 Glazing Material.
17.3 Kinds of Windows.
17.4 Setup.
17.5 Closing Tools.


Chapter 18 Glass Block Assemblies.


18.1 General.
18.2 Installation.


Chapter 19 Installation, Examining, and also Maintenance of Fire Dampers.


19.1 General.
19.2 Installment.
19.3 Functional Test.
19.4 Acceptance Screening.
19.5 Regular Checking.
19.6 Upkeep.
19.7 Area Modifications.


Phase 20 Material Fire Safety Curtains.


20.1 General.
20.2 Textile Fire Safety Curtain Elements.
20.3 Installment.
20.4 Fire Safety Curtain Assemblies.
20.5 Supporting Building.
20.6 Rigging as well as Lifting Tools.
20.7 Operation of the Fire Safety Curtain Setting Up.
20.8 Approval Screening.
20.9 Treatment and also Upkeep.


Phase 21 Fire Protective Drape Assemblies.


21.1 General.
21.2 Placing of Fire Safety Drape Assemblies.
21.3 Assembly Elements.
21.4 Power Operators.
21.5 Installment.
21.6 Assessment, Testing, and Upkeep.
21.7 Acceptance Testing.
21.8 Closing Gadgets.
21.9 Regular Inspection as well as Testing.
21.10 Maintenance.


Annex A Explanatory Product.
Annex B Fire Doors: Security of Conveyor Openings.
Annex C Illustration of Kinds Of Fire Window Components.
Annex D Fire Door and also Fire Home Window Classifications.
Annex E Surface Area Add-ons to Turning Door Deals With.
Annex F Door Equipment Locations.
Annex G Kinds Of Door Building.
Annex H Special Function Doors.
Annex I Convected Heat Transfer.
Annex J Performance-Based Option for the Examination, Screening, and also Maintenance of Fire Door Assemblies.
Annex K General Information About Fire Doors.
Annex L Informational References.


Related News

content is empty!

CE, UL, ANSI/BHMA Certified Hardware for Metal Doors, Fire Rated Doors, Wooden Doors etc. We have Rich Experience working with Famous Brands, Door Factories, Proiect Contractor, etc.

Quick Links

Product Category

Support

Coutant
Get Famous Branded Quality at Factory Cost
Tel / WhatsApp / Wechat:
+86-13929037292
ADD: 
12th Floor, Building 2, No.898, KeChuang Technical Zone, Jiangmen Avenue, Pengjiang District, Jiangmen City, Guangdong, China 529000
E-mail: 
(David Jian)
(Ms Judy)
 Copyright ©️ 2023 D&D HARDWARE INDUSTRIAL Co., Ltd. All Rights Reserved | Sitemap
We use cookies to enable all functionalities for best performance during your visit and to improve our services by giving us some insight into how the website is being used. Continued use of our website without having changed your browser settings confirms your acceptance of these cookies. For details please see our privacy policy.
×